Setting Meta Horizon Link as the Active OpenXR Runtime on locked-down Windows environments.
Manual configuration – Guide
Context: When the Meta Horizon Link app’s built-in “Set Meta Horizon Link as active OpenXR runtime” button is unavailable, greyed out, or its auto-registration doesn’t take effect, the runtime can be set by hand. The OpenXR loader resolves the active runtime from a machine-level registry value.
Work through the steps in order. Step 1 is the actual fix. While 2–4 are checks for environments where step 1 is not sufficient.
Runtime location. The current Meta Horizon Link runtime installs to the folder below.
This path changed in late 2025, as they rebranded from “Program Files\Oculus” so confirm that the files physically exists on the target machine before continuing: “C:\Program Files\Meta Horizon\Support\oculus-runtime\“
1) HKEY_LOCAL_MACHINE registry (the primary fix)
This machine-level key is the authoritative source the OpenXR loader uses to locate the active runtime.
64-bit applications
- Key:
HKEY_LOCAL_MACHINE\SOFTWARE\Khronos\OpenXR\1 - Value name:
ActiveRuntime
(type: String / REG_SZ) - Value data:
C:\Program Files\Meta Horizon\Support\oculus-runtime\oculus_openxr_64.json

32-bit applications (optional — only if a 32-bit OpenXR app is used)
- Key:
HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\Khronos\OpenXR\1 - Value name:
ActiveRuntime(type: String / REG_SZ) - Value data:
C:\Program Files\Meta Horizon\Support\oculus-runtime\oculus_openxr_32.json
Note this has _32.json, not 64. The runtime bitness must match the app.
Common mistakes made:
- The value name must be exactly
ActiveRuntime, the data is the path “C:\Prog…”. Many swap name and data, when creating this from scratch. - The value type must be String (REG_SZ) — not REG_EXPAND_SZ or a multi-string.
- Path or names should not be quoted ” “.
- The file it points to must actually exist. Open the folder and confirm that
oculus_openxr_64.jsonis present in that folder. A path to a missing file is the single most common cause of “Current runtime = none / unknown.” - Writing HKEY_LOCAL_MACHINE requires local administrator rights. In a managed environment this is normally pushed via GPO / Intune / MDM or an admin script rather than set by the end user.
Restart Meta Horizon Link app, to check it has taken effect.

When successful your Meta Horizon Link settings page should show this.

If it works, great, you are done.
If not, check that step 1 is correct. If it is but the runtime still won’t register, something else is interfering. Below are what to check, or look out for.
2) Rule out overrides
- Environment variable: Confirm it is NOT set.
A leftoverXR_RUNTIME_JSONvariable (User or System scope) can redirect the loader.
Important: the OpenXR loader deliberately ignores XR_RUNTIME_JSON for any process running at medium integrity or higher – which is effectively every normal application. This means the variable cannot be used as a fix. If present and stale it causes confusion. If you have one, remove it and rely on step 1. - HKEY_CURRENT_USER – do not rely on it.
Same advice as for the Environment variable, theHKEY_CURRENT_USER\is not consulted by the loader. Delete it to avoid a false fix. - Another runtime claiming “active.”
SteamVR, Virtual Desktop, Windows Mixed Reality (legacy), or Varjo Base can overwrite the HKEY_LOCAL_MACHINE ActiveRuntime value to point at themselves. Sometimes on every launch. After launching and closing other VR software you consider using, re-check that the HKEY_LOCAL_MACHINE value still points at the Meta Horizon json.
3) JSON file read permissions
Strict endpoint policy can stop a standard user from reading configuration files invoked by an external loader, even inside C:\Program Files\. If the loader cannot read the json, it fails silently and the runtime never registers.
- Open
C:\Program Files\Meta Horizon\Support\oculus-runtime\ - Right-click
oculus_openxr_64.json→ Properties → Security - Confirm the Users group (or the specific domain user) has at least Read permission. Apply the same check to the oculus-runtime folder.
4) Endpoint security / AppLocker (silent blocks)
Even with the registry perfect, endpoint protection (CrowdStrike, Microsoft Defender / AppLocker, CyberArk, etc.) can silently block the runtime from initializing. The json instructs the loader to load the runtime DLL — LibOVRRTImpl64_1.dll (the file named in the json’s library_path, located in the same folder) — into the application’s process. If that folder isn’t allow-listed for execution / module load, the DLL is blocked even when read access is fine.
- Check endpoint / AppLocker logs for blocks on
C:\Program Files\Meta Horizon\Support\oculus-runtime\* - Ensure that path — and its DLLs, especially
LibOVRRTImpl64_1.dll— is allow-listed for execution / module load, not only read access.
Quick verification
- Open regedit and confirm
HKLM\SOFTWARE\Khronos\OpenXR\1\ActiveRuntimeequals the 64-bit json path above. - Confirm that json file actually exists on disk.
- Launch Meta Quest Link: it should now show Meta Horizon as the openXR runtime.
- Opening the XR application: it should now show “Oculus” as the openXR runtime.
(Why Oculus? Meta’s rebranding has not reach every corner of their systems yet)